| Item | Characteristics |
| Operating Temperature Range(℃) | -40-+85 |
| Capacitance Tolerance(20℃, 120Hz) | ±20% |
| Leakage Current(μA) | 0.01CV or 3 whichever is greater. (at 20℃,after 2 minutes) C:Nominal Capacitance(μF), V:Rated Voltage(v) |
| Dissipation Factor(20,℃120Hz) | | Rated voltage(v) | 4 | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 | | tanδ | 0.35 | 0.24 | 0.20 | 0.16 | 0.14 | 0.12 | 0.10 | 0.08 | 0.08 |
|
| Temperature Stability (120Hz) | | Rated voltage(v) | 4 | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 | | Impedance ratio | z-25℃/Z+20℃ | 6 | 4 | 3 | 2 | | z-40℃/Z+20℃ | 16 | 10 | 8 | 6 | 4 |
|
| Load Life(+85℃) | | Time | 1000hours. | | Leakage current | Not more than the specified value | | Capacitance change | within±20% of initial value | | Dissipation factor | Not more than 200% of the specified value. |
|
| Shelf Life (+85℃) | 500hours. No voltage appiled. After test:UR to be applied for 30 minutes, 24to 48 hours before measurement. |