| Item | Characteristics |
| Operating Temperature Range(℃) | -55~+105 | -40~+105 |
| Rated Voltage Range(V) | 6.3~100 | 160~450 |
| Capacitance Tolerance(20℃,120Hz) | ±20% |
| Leakage current(μA) | 0.01CV or 3 whichever is greater.(at 25℃,after 2 minutes) | CV≤1000:0.1CV+40(at 20℃,after 1 minute) CV>1000:0.04CV+100(at 20℃,after 1 minute) |
C:Nominal Capacitance(μF) V:Rated Voltage(V) |
| Dissipation Factor(20℃,120Hz) | | Rated voltage(v) | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 | 160 | 200 | 250 | 315 | 350 | 400 | 450 | | tanδ | 0.22 | 0.19 | 0.16 | 0.14 | 0.12 | 0.10 | 0.09 | 0.08 | 0.15 | 0.15 | 0.15 | 0.20 | 0.20 | 0.20 | 0.20 | when nominal capacitance is over 1000uF tanδ shall be added 0.02 to the listed value with increase of every 1000 uF |
| Temperature Stability(120Hz) | | Rated voltage(v) | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 | | Impedance Ratio | Z-25℃/Z+20℃ | 4 | 3 | | | Z-40℃/Z+20℃ | 8 | 6 | 4 | 3 |
| Rated voltage(v) | 160~250 | 315~450 | | Impedance Ratio | Z-25℃/Z+20℃ | 3 | | Z-40℃/Z+20℃ | 8 | 6 |
|
| Load Life(105℃) | | Time | 2000 hours(ΦD≤ 8, 1000 hours) | | Leakage current | Not more than the specified value. | | Capacitance Change | within ±20% of the initial value. | | Dissipation Factor | Not more than 200% of the specified value. |
|
| Shelf Life(105℃) | 1000 hours,No voltage applied. After test:UR to be applied for 30 minutes,24 to 48 hours before measurement. |