| Item | Characteristics |
| Operating Temperature Range(℃) | -40~+125 |
| Capacitance Tolerance(20℃,120Hz) | ±20% |
| Leakage current(μA) | 0.002CV or 2μA whichever is greater.(at 20℃, after 5 minutes) C:Nominal Capacitance(μF) V:Rated Voltage(V) |
| Dissipation Factor(20℃,120Hz) | | Rated voltage(V) | 10 | 16 | 25 | 35 | 50 | 63 | 100 | | tanδ | 0.20 | 0.17 | 0.17 | 0.12 | 0.10 | 0.10 | 0.10 |
|
| Temperature Stability(120Hz) | | Rated Voltage(V) | 10 | 16 | 25 | 35 | 50 | 63 | 100 | | Impedance Ratio | Z-25℃/Z+20℃ | 2 | 2 | 2 | 2 | 2 | 2 | 2 | | Z-40℃/Z+20℃ | 8 | 6 | 4 | 4 | 4 | 4 | 3 |
|
| Load Life(125℃) | | time | 1000 hours | | Leakage Current | Not more than the speecified value. | | Capacitance Change | Within ±15% of the initial value. | | Dissipation Factor | Not more than 150% of the specified value. |
|
| Shelf Life(125℃) | 500hours. No voltaeg appiled. After test:UR to be applied for 30 minutes, 24 to 48 hours before measurement. |