| Item | Characteristics |
| Operating Temperature Range(℃) | -40~+85(450~500WV:-25~+85) |
| Capacitance Tolerance(20℃,120Hz) | ±20% |
| Leakage current(μA) | 0.01CV or 1.5mA whichever is smaller(at 20℃ ,after 5 minutes) C:Nominal Capacitance(μF) V:Rated Voltage(V) |
| Dissipation Factor(20℃,120Hz) | | Rated voltage(v) Cap(μF) | 10-16 | 25 | 35-50 | 63 | 80-100 | | ~2700 | - | - | 0.20 | 0.15 | 0.15 | | 3300-4700 | - | 0.35 | 0.25 | 0.20 | 0.15 | | 5600-6800 | 0.40 | 0.35 | 0.30 | 0.20 | 0.20 | | 8200~ | 0.40 | 0.35 | 0.35 | 0.25 | - |
| Rated voltage(v) ΦD(mm) | 160-200 | 250-500 | | 35 | 0.12 | 0.15 |
|
| Temperature Stability(120Hz) | | Rated voltage(v) | 10 | 16-35 | 50-100 | 160-200 | 250-400 | 450~500 | | Impedance Ratio | Z-25℃/Z+20℃ | 5 | 4 | 3 | 3 | 4 | 4 | | Z-40℃/Z+20℃ | 18 | 15 | 10 | 6 | 8 | - |
|
| Load Life(+85℃) | | Time | 2000 hours | | Leakage Current | Not more than the specified value. | | Capacitance Change | Within±20% of the initial value. | | Dissipation Factor | Not more than 200% of the specified value. |
|
| Shelf Life(+85℃) | | Time | 1000 hours | | Leakage Current | Not more than the specified value. | | Capacitance Change | Within±15% of the initial value. | | Dissipation Factor | Not more than 150% of the specified value. |
After test:UR to be applied for 60 minutes, 24 to 48 hours before measurement. |