| Frequency Range | 1-100MHz |
| Frequency Accuracy | ±0.5PPM(center control voltage) |
| FrequencyStability vs Temperature | See Table 1 |
(AT Cut) Aging (SC Cut)
| ±0.001PPM/Day,first year±0.1PPM,10year±1PPM ±0.001PPM/Day,first year±0.1PPM,10year±1PPM |
| Output Type and Load Characteristics | See Table 2 |
| Frequency Stability vs Load | ±0.02PPM vs ±10% load change |
| Supply Voltage | +5.0VDC,+12.0VDC |
| Frequency Stability vs Voltage | ±0.02PPM vs ±5% voltage change |
| Supply Consumption | 3.6W(max.)when warm-up;1.20W(max.)when static |
(AT Cut) Warm-up Time (SC Cut)
| ±0.2PPM,<1min. ±0.05PPM,<1min. |
(AT Cut) Adjustable Frequency Range (SC Cut)
| ±7.0PPM ±1.0PPM |
| Control Voltage Range | 0-5V |
| Slope | Positive |
| Linearity | ±10% |
| Phase Noise(10MHz) | 1Hz,-80dBc/Hz 10Hz,-120dBc/Hz 100Hz,-140dBc/Hz 1kHz,-145dBc/Hz 10kHz,-150dBc/Hz |
| Storage Temperature Range | -40-+100°C |